Home
The Systems Depot Catalog
about

 
  Fire Alarm Control - Addressable
The Systems Depot
  Application Specifications Features

  • FIRMS9050UD

    MS-9050UD 50-Point Addressable Control Panel
    Small Commercial Fire • 50 points of either detection or modules
    • 2 Class A or Class B NAC circuits
    • 2.5 A total NAC power
    • Single SLC that meets Style 4, 6 or 7 requirements
    • Auto-program (learn mode) reduces installation time
    • On-board DACT
    • 20 software zones
    • Selectable strobe synchronization for System Sensor, Gentex and Wheelock devices

  • FIRMS9200UDLS

    MS-9200UDLS 198-Point Addressable Control Panel
    Small to mid commercial Fire • 198 addressable points: 99 detectors and 99 modules
    • Four onboard NACs with additional NAC capability
    • 2.5 amps maximum per each NAC circuit
    • SLC can be configured for NFPA Style 4, 6, or 7 operation
    • On-board DACT
    • Four Class B or two Class A NAC circuits
    • Selectable strobe synchronization for System Sensor, Wheelock and Gentex devices
    • Up to 32 ACM Series (ACM-16AT or ACM-32 series) annunciators or LCD-80F remote annunciators via EIA-485

  • FIRMS9600

    MS-9600 Addressable Fire Alarm Control Panel with DACT
    Individually identifies each alarm initiating device on the system • DACT-UD Optional digital dialer modem for remote upload/download
    • Programmable via on-board keypad, PC keyboard, local Laptop or Remote
    • Four on-board Notification Circuits, with built-in NAC sync, supported by 6 Amps of NAC power
    • Second SLC option allowing for a combined total of 636 points (SLC-2)
    • 159 smoke/heat detectors and 159 control/relay/monitor modules per SLC
    • Optional DACT with remote upload/download allows panel programs to be downloaded to the system from off-site locations
    • Supports a wide range of addressable devices capable of handling most design specs
    • Ease of programming with auto-programming feature, allowing the system to establish fire protection within a few seconds
    • Built-in NAC Synch for System Sensor, Wheelock and Gentex devices, removing the need for additional hardware

  • POTPFC9000R

    3992150 127 Points With 12 AMP Power Supply
    Individually identifies each alarm initiating device on the system • Common control switches and/or indicating LEDs for System Reset, Signal Silence, and Fire Drill
    • Front panel auto-configure and /or computer laptop programmable
    • RS-232 output for remote system printer or CRT
    • Four class A/B (Style Z/Y) notification circuits rated at 1.7 Amps each
    • Each analog loop is capable of supporting 127 analog sensors and addressable modules
    • 12 amp power supply standard
    • Allows sensitivity adjustment of smoke detectors
    • Optional 4 NAC adder card & 8 relay card
    • Optional 8 zone hardwire adder module – great for retrofits!
    • Expandable to 3 loops (381 points)

  • SIL5700

    5700 Single Loop Addressable Fire Alarm Control Panel
    Addressable fire alarm control for small applications. • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC
    • Central station reporting by point or by zone
    • Built-in digital communicator
    • Uses standard wire – no shielded or twisted pair required
    • Up to 50 addressable points
    • No additional cost for a Dialer because it is built-in
    • Lower Cost Installation because standard wire can be used
    • Low Cost Control
The Systems Depot